Seitenansicht 120
Product Errata 121
Revision Guide for AMD Family 10h Processors
41322 Rev. 3.84 August 2011
407 System May Hang Due to Stalled Probe Data Transfer
Description
Under highly detailed and specific internal timing conditions, a processor that has one or more
processor cores in a cache-flushed state following a C1E exit, and one or more cores executing in C0
state, may not complete a data transfer for a probe.
Potential Effect on System
System hang.
Suggested Workaround
Contact your AMD representative for information on a BIOS update.
This workaround requires that Clock Power/Timing Control 2 Register[CacheFlushOnHaltTmr]
(F3xDC[25:19]) is greater than 01h, which is true under normal circumstances.
Fix Planned
Yes